{"id":9392,"date":"2026-11-26T19:20:54","date_gmt":"2026-11-26T11:20:54","guid":{"rendered":"https:\/\/topsilsilicone.com\/?post_type=product&#038;p=9392"},"modified":"2026-11-27T17:59:01","modified_gmt":"2026-11-27T09:59:01","slug":"high-temperature-silicone-potting-compound","status":"publish","type":"product","link":"https:\/\/topsilsilicone.com\/ko\/product\/high-temperature-silicone-potting-compound\/","title":{"rendered":"300\u00b0C High-Temperature Silicone Potting Compound"},"content":{"rendered":"<p>TP-8850 is a two-part, addition-cure silicone potting compound for high-temperature applications in purification equipment and power supplies. It cures to a Shore A 50 \u00b1 5 rubber. For filter manufacturers evaluating a poured joint between the media pack and frame, the first questions are which surfaces the silicone will contact and what temperature the joint will reach in service.<\/p>\n<p><strong>Mix ratio:<\/strong> 1:1 by weight \u00a0\u00b7\u00a0 <strong>Mixed viscosity:<\/strong> 2,500 \u00b1 500 cP \u00a0\u00b7\u00a0 <strong>Working time:<\/strong> 30\u201340 minutes at 25\u00b0C and 65% relative humidity.<\/p>\n<p><!-- \u9876\u90e8\u54a8\u8be2\u6309\u94ae --><\/p>\n<div style=\"margin: 0; padding-bottom: 32px;\"><a style=\"display: inline-block; padding: 10px 20px; border-radius: 15px; background-color: #ff6000; color: #ffffff; font-size: 15px; font-weight: 500; line-height: 20px; text-decoration: none;\" href=\"https:\/\/topsilsilicone.com\/ko\/%eb%ac%b8%ec%9d%98%ed%95%98%ea%b8%b0\/\">Discuss My TP-8850 Application<\/a><\/div>\n<p><!-- \u7ea2\u767d\u7ec4\u5206\u56fe\u7247 --><\/p>\n<figure class=\"wp-block-image size-large\" style=\"margin: 0 0 24px;\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-9398 size-large lazyload\" style=\"display: block; max-width: 100%; height: auto;\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-red-white-silicone-components-1024x576.webp\" alt=\"Illustration of red Part A and white Part B in separate cups beside a pleated filter.\" width=\"800\" height=\"450\" \/><noscript><img decoding=\"async\" class=\"alignnone wp-image-9398 size-large lazyload\" style=\"display: block; max-width: 100%; height: auto;\" src=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-red-white-silicone-components-1024x576.webp\" alt=\"Illustration of red Part A and white Part B in separate cups beside a pleated filter.\" width=\"800\" height=\"450\" srcset=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-red-white-silicone-components-1024x576.webp 1024w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-red-white-silicone-components-300x169.webp 300w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-red-white-silicone-components-768x432.webp 768w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-red-white-silicone-components-1536x864.webp 1536w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-red-white-silicone-components-18x10.webp 18w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-red-white-silicone-components-600x338.webp 600w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-red-white-silicone-components.webp 1600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/noscript><\/figure>\n<h2>What does the 300\u00b0C figure mean for my application?<\/h2>\n<p>The TP-8850 technical data sheet lists a material temperature-resistance range of <strong>\u221250\u00b0C to 300\u00b0C<\/strong>. It gives no continuous operating time or allowable peak duration at 300\u00b0C. To evaluate a particular joint, share its normal operating temperature, peak temperature, time at peak and expected number of heating cycles.<\/p>\n<p>If you only know the oven setpoint or process air temperature, include that figure and identify where it was measured. This helps the engineering team decide what to measure during a sample trial.<\/p>\n<figure class=\"wp-block-image size-large\" style=\"margin: 0 0 24px;\"><img decoding=\"async\" class=\"alignnone wp-image-9399 size-large lazyload\" style=\"display: block; max-width: 100%; height: auto;\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-joint-temperature-probe-1024x576.webp\" alt=\"Thermocouple tip positioned at the joint between the filter media and the metal frame.\" width=\"800\" height=\"450\" \/><noscript><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-9399 size-large lazyload\" style=\"display: block; max-width: 100%; height: auto;\" src=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-joint-temperature-probe-1024x576.webp\" alt=\"Thermocouple tip positioned at the joint between the filter media and the metal frame.\" width=\"800\" height=\"450\" srcset=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-joint-temperature-probe-1024x576.webp 1024w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-joint-temperature-probe-300x169.webp 300w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-joint-temperature-probe-768x432.webp 768w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-joint-temperature-probe-18x10.webp 18w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-joint-temperature-probe-600x338.webp 600w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-joint-temperature-probe.webp 1280w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/noscript><\/figure>\n<h2>Where will the silicone sit in your HEPA filter assembly?<\/h2>\n<p><strong>Media-pack-to-frame joint.<\/strong> If the filter design calls for a fixed, poured rubber joint, evaluate TP-8850 on a representative section of the frame and media edge. Include the actual frame finish, coatings and existing adhesives. Bond strength at these interfaces and leakage performance of the finished filter require testing on the intended assembly.<\/p>\n<figure class=\"wp-block-image size-large\" style=\"margin: 0 0 24px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-9400 size-large lazyload\" style=\"display: block; max-width: 100%; height: auto;\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/hepa-media-pack-to-frame-potting-1024x576.webp\" alt=\"Cutaway showing the potting material between the pleated filter media and the aluminum frame.\" width=\"800\" height=\"450\" \/><noscript><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-9400 size-large lazyload\" style=\"display: block; max-width: 100%; height: auto;\" src=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/hepa-media-pack-to-frame-potting-1024x576.webp\" alt=\"Cutaway showing the potting material between the pleated filter media and the aluminum frame.\" width=\"800\" height=\"450\" srcset=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/hepa-media-pack-to-frame-potting-1024x576.webp 1024w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/hepa-media-pack-to-frame-potting-300x169.webp 300w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/hepa-media-pack-to-frame-potting-768x432.webp 768w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/hepa-media-pack-to-frame-potting-18x10.webp 18w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/hepa-media-pack-to-frame-potting-600x338.webp 600w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/hepa-media-pack-to-frame-potting.webp 1280w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/noscript><\/figure>\n<p><strong>Knife-edge gel channel.<\/strong> If a housing blade seats in a soft, tacky gel when the filter is installed, see <a href=\"https:\/\/topsilsilicone.com\/ko\/product\/%ec%97%90%ec%96%b4-%ed%95%84%ed%84%b0-%eb%b0%80%eb%b4%89\/\">TP-012 silicone gel for HEPA filter sealing<\/a>. Include the temperature at the gel channel when requesting a recommendation.<\/p>\n<h2>TP-8850 technical data<\/h2>\n<figure class=\"wp-block-table\">\n<table>\n<caption>Selected values from the TP-8850 technical data sheet. Stated test conditions are 25\u00b0C and 65% relative humidity.<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">\uc18d\uc131<\/th>\n<th scope=\"col\">TDS value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Component colors<\/th>\n<td>Part A is red. Part B is white.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Mix ratio, A to B<\/th>\n<td>1:1 by weight<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\uc810\uc131<\/th>\n<td>Part A, Part B and mixed material each measure 2,500 \u00b1 500 cP<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\uadfc\ubb34 \uc2dc\uac04<\/th>\n<td>30\u201340 minutes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Initial cure time<\/th>\n<td>1\u20132 hours<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cured hardness<\/th>\n<td>Shore A 50 \u00b1 5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Thermal conductivity<\/th>\n<td>0.65 W\/(m\u00b7K)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2>Will TP-8850 fit your mixing and dispensing process?<\/h2>\n<p>Weigh equal amounts of Part A and Part B. Mix by hand or machine until the color is uniform, then vacuum-degas the mixture to remove entrapped air. Pour within the working time and allow the assembly to cure at room temperature. When sizing a batch, count the time needed for mixing, degassing and filling the last joint.<\/p>\n<figure class=\"wp-block-image size-large\" style=\"margin: 0 0 24px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-9401 size-large lazyload\" style=\"display: block; max-width: 100%; height: auto;\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-filter-frame-joint-819x1024.webp\" alt=\"Close-up of red silicone along the lower joint between the pleated filter pack and its metal frame.\" width=\"800\" height=\"1000\" \/><noscript><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-9401 size-large lazyload\" style=\"display: block; max-width: 100%; height: auto;\" src=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-filter-frame-joint-819x1024.webp\" alt=\"Close-up of red silicone along the lower joint between the pleated filter pack and its metal frame.\" width=\"800\" height=\"1000\" srcset=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-filter-frame-joint-819x1024.webp 819w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-filter-frame-joint-240x300.webp 240w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-filter-frame-joint-768x960.webp 768w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-filter-frame-joint-10x12.webp 10w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-filter-frame-joint-600x750.webp 600w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-filter-frame-joint.webp 1122w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/noscript><\/figure>\n<p><strong>When can a filled frame be moved or heated?<\/strong> The published 1\u20132 hours refers to initial cure at 25\u00b0C and 65% relative humidity. Establish the handling time at your production temperature and fill depth. Agree on a cure schedule before the first heat exposure.<\/p>\n<p><strong>What if the dispenser meters by volume?<\/strong> Verify the delivered weights of Part A and Part B against the specified 1:1 weight ratio before evaluating the cured material.<\/p>\n<p><strong>Will the silicone cure against the frame coating?<\/strong> The TDS identifies possible cure inhibitors, including organotin compounds, sulfur-containing materials, amines and flux residues. A small trial on the actual contact surfaces lets you inspect the cured interface before filling a complete frame.<\/p>\n<h2>How should a filter manufacturer evaluate a sample?<\/h2>\n<ol>\n<li><strong>Prepare a representative joint.<\/strong> Record the frame material and finish, media edge, existing adhesive, fill depth and cure conditions. Keep a reference specimen for comparison.<\/li>\n<li><strong>Run the intended heat cycle.<\/strong> Record temperature, time at peak, cooling conditions and number of cycles. Where possible, measure the temperature at the joint. Define in advance which changes would fail the trial, such as cracking or separation from the frame.<\/li>\n<li><strong>Check the finished assembly.<\/strong> Inspect the joint after cooling and document the observations against the agreed criteria. Where the finished filter has a leakage requirement, verify it using the procedure specified for that filter.<\/li>\n<\/ol>\n<figure class=\"wp-block-image size-large\" style=\"margin: 0 0 24px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-9403 size-large lazyload\" style=\"display: block; max-width: 100%; height: auto;\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-potting-trial-inspection-1024x576.webp\" alt=\"Magnifier over the media-to-frame interface of one of two filter joint specimens.\" width=\"800\" height=\"450\" \/><noscript><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-9403 size-large lazyload\" style=\"display: block; max-width: 100%; height: auto;\" src=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-potting-trial-inspection-1024x576.webp\" alt=\"Magnifier over the media-to-frame interface of one of two filter joint specimens.\" width=\"800\" height=\"450\" srcset=\"https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-potting-trial-inspection-1024x576.webp 1024w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-potting-trial-inspection-300x169.webp 300w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-potting-trial-inspection-768x432.webp 768w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-potting-trial-inspection-18x10.webp 18w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-potting-trial-inspection-600x338.webp 600w, https:\/\/topsilsilicone.com\/wp-content\/uploads\/filter-frame-potting-trial-inspection.webp 1280w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/noscript><\/figure>\n<h2>Packaging and storage<\/h2>\n<p>TP-8850 is available in 50 kg sets (25 kg A + 25 kg B) and 200 kg sets (100 kg A + 100 kg B). The stated shelf life is 18 months. Store the containers in a cool, dry place and protect them from rain and direct sunlight.<\/p>\n<h2>Discuss your TP-8850 application<\/h2>\n<p>Enter <strong>TP-8850<\/strong> in the Project Requirements field and tell us where the silicone will be poured. For a sample evaluation, include the contact surfaces and the temperature cycle you know. For a quotation, add the quantity and delivery destination.<\/p>\n<p>A short description is enough to start. For example: \u201cWe are evaluating TP-8850 for a coated steel filter frame. We know the oven setpoint and cycle time, but have not yet measured the joint temperature. What information do you need to review a sample request?\u201d<\/p>\n<p><!-- \u5e95\u90e8\u54a8\u8be2\u6309\u94ae\uff0c\u4e0e\u9876\u90e8\u6309\u94ae\u6837\u5f0f\u4e00\u81f4 --><\/p>\n<div style=\"margin: 0;\"><a style=\"display: inline-block; padding: 10px 20px; border-radius: 15px; background-color: #ff6000; color: #ffffff; font-size: 15px; font-weight: 500; line-height: 20px; text-decoration: none;\" href=\"https:\/\/topsilsilicone.com\/ko\/%eb%ac%b8%ec%9d%98%ed%95%98%ea%b8%b0\/\">Discuss My TP-8850 Application<\/a><\/div>","protected":false},"excerpt":{"rendered":"<p>Evaluating a potting compound for the joint between a HEPA filter media pack and its frame?<\/p>\n<p>TP-8850 is a two-part silicone that pours into the joint and cures to a firm rubber.<\/p>\n<p>Mix ratio 1:1 by weight \u00b7 Working time 30\u201340 min at 25\u00b0C and 65% RH \u00b7<\/p>\n<p>Cured hardness Shore A 50 \u00b1 5.<\/p>\n<p>The data sheet lists a material temperature range of \u221250\u00b0C to 300\u00b0C.<\/p>\n<p>To discuss a sample trial, tell us your frame material, peak joint temperature and time at peak.<\/p>","protected":false},"featured_media":9426,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":""},"product_brand":[],"product_cat":[139],"product_tag":[],"class_list":["post-9392","product","type-product","status-publish","has-post-thumbnail","product_cat-potting-encapsulation-silicone","first","instock","shipping-taxable","product-type-simple"],"uagb_featured_image_src":{"full":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero.webp",1200,1500,false],"thumbnail":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero-150x150.webp",150,150,true],"medium":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero-240x300.webp",240,300,true],"medium_large":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero-768x960.webp",768,960,true],"large":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero-819x1024.webp",800,1000,true],"1536x1536":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero.webp",1200,1500,false],"2048x2048":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero.webp",1200,1500,false],"trp-custom-language-flag":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero-10x12.webp",10,12,true],"woocommerce_thumbnail":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero-300x300.webp",300,300,true],"woocommerce_single":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero-600x750.webp",600,750,true],"woocommerce_gallery_thumbnail":["https:\/\/topsilsilicone.com\/wp-content\/uploads\/tp-8850-hepa-filter-assembly-hero-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Brian","author_link":"https:\/\/topsilsilicone.com\/ko\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Evaluating a potting compound for the joint between a HEPA filter media pack and its frame? TP-8850 is a two-part silicone that pours into the joint and cures to a firm rubber. Mix ratio 1:1 by weight \u00b7 Working time 30\u201340 min at 25\u00b0C and 65% RH \u00b7 Cured hardness Shore A 50 \u00b1 5.&hellip;","_links":{"self":[{"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/product\/9392","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/comments?post=9392"}],"version-history":[{"count":5,"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/product\/9392\/revisions"}],"predecessor-version":[{"id":9424,"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/product\/9392\/revisions\/9424"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/media\/9426"}],"wp:attachment":[{"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/media?parent=9392"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/product_brand?post=9392"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/product_cat?post=9392"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/topsilsilicone.com\/ko\/wp-json\/wp\/v2\/product_tag?post=9392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}